BEST PRICE ON LINE AUTHORIZED DEALER
Place a bid
READY MADE RESOURCES IS A PROUD AUTHORIZED DEALER OF SUNNY BOY PRODUCTSIF YOU HAVE ANY QUESTIONS ON THIS PRODUCT PLEASE CALL US AT 800-627-3809WE WELCOME INTERNATIONAL SALESPAYMENT METHOD MUST BE APPROVED FOR INTERNATIONAL SALESWE ARE APPROVED FOR THE CALIFORNIA REBATE PROGRAM
Xantrex
XW Hybrid Inverter/Chargers
XW4024, XW4548, XW6048
Xantrex brings the next generation of inverter/charger to market, with the XW Hybrid Inverter/
Charger, the heart of the XW System. The XW Hybrid Inverter/Charger (XW) is a true sine wave,
120/240-volt AC, split-phase, inverter/charger that incorporates a DC to AC inverter, a battery
charger, and an AC auto-transfer switch. It is the foundation for battery- based residential and
commercial applications up to 18 kilowatts (kW). Capable of being grid-interactive or gridindependent,
the XW can operate with generators and renewable energy sources to provide
full-time or backup power.
Designed with consultation and input from industry experts, dealers, and installers, the XW sets
a new standard for battery-based inverter/chargers.
Integrating the best features available in the market, innovative new
features by Xantrex and balance-of-systems components, the XW Hybrid
Inverter/Charger’s design makes installation quicker and easier. The XW
offers high efficiency and unprecedented surge capacity to maximize the
owner’s return on investment. No other inverter/charger looks or
performs like the XW.
Features
True sine wave output 120/240 volt AC spilt-phase operation Dual AC inputs Integrated design to minimize external balance-of-system components XanBus™-enabled network communication Certified to UL1741 and CSA for utility-interactive applications Unprecedented surge capacity Efficient, power factor corrected, high-current, multistage battery charging
Optional Accessories:
Specifications
Electrical Specifications
XW6048-120/240-60
XW4548-120/240-60
XW4024-120/240-60
Continuous output power
6,000 W
4500 W
4000 W
Surge rating (10 seconds)
12,000 W
9000 W
8000 W
Surge current
L-N: 105 Arms (7 sec)
L-L: 40 Arms (20 sec)
L-L: 52.5 Arms (7 sec)
L-N: 70 Arms (20 sec)
L-N: 75 Arms (20 sec)
L-L: 35 Arms (20 sec)>
Waveform
True sine wave
True sine wave
True sine wave
Low-load efficiency
95%
95%
95%
Idle consumption - search mode
< 8 W
< 8 W
< 8 W
AC connections
AC1 (Grid), AC2 (Generator)
AC1 (Grid), AC2 (Generator)
AC1 (Grid), AC2 (Generator)
AC voltage
120/240 Vac split-phase
120/240 Vac split-phase
120/240 Vac split-phase
AC input breaker
60 A two-pole
60 A two-pole
60 A two-pole
Utility interactive
Yes
Yes
Yes
CEC weighted efficiency
92.5%
93%
91%
CEC power rating
5752 W
4500 W
4000 W
AC input voltage range (bypass/charge mode)
L-N: 80 - 150 Vac (120 V nominal); L-L: 160 - 270 Vac (240 V nominal)
AC input frequency range (bypass/charge mode)
55 - 65 Hz (default); 44 - 70 Hz (allowable)
AC1 voltage range – Sell mode
(automatically adjusts when entering Sell mode)*
L-N: 108 - 130 +/- 1.5 Vac; L-L: 214 - 260 +/- 3.0 Vac
AC1 frequency range – Sell mode
(automatically adjusts when entering Sell mode)*
59.4 - 60.4 +/- 0.05 Hz
AC output voltage
L-N: 120 Vac +/- 3%; L-L: 240 Vac +/- 3%
AC output frequency
60.0 +/-0.1 Hz
DC current at rated power
130 A
96 A
178 A
Total harmonic distortion
< 5%
Automatic transfer relay
60 A
Typical transfer time
8 ms
DC input voltage (nominal)
50.4 Vdc
50.4 Vdc
25.2 Vdc
DC input voltage range
44 - 64 Vdc
44 - 64 Vdc
22 - 32 Vdc
Maximum continuous charge rate
100 A
85 A
150 A
Efficiency at maximum charge rate
89.4%
90.2%
85.8%
Power factor corrected charging
0.98
0.98
0.98
Emissions
FCC Class B
FCC Class B
FCC Class B
Multiple-unit configurations
Up to three parallel units in 120/240-volt split-phase configuration
Auxiliary relay output
0-12 Vdc, maximum 250 mA DC
Non-volatile memory
Yes
Yes
Yes
System network
Xanbus™ (publish-subscribe network, no need for hubs or special cards)
Mechanical Specifications
Mounting
Wall mount, backplate included
Inverter dimensions (H x W x D)
23 x 16 x 9” (580 x 410 x 230 mm)
Inverter weight
125 lb (57 kg)
115 lb (52 kg)
115 lb (52 kg)
Shipping dimensions
28 x 22 ¼ x 10 ½” (711 x 565 x 267 mm)
Shipping weight
132 lb (60 kg)
122 lb (55 kg)
122 lb (55 kg)
Display panel
Status LEDs indicate AC In status, faults/warnings, equalize mode, battery level. Three-character display indicates output power
or charge current, fault/warning codes. On/Off and equalize buttons
Battery temperature sensor
Included
Included
Included
Standard warranty
Five years
Five years
Five years
Part number
865-1000
865-1005
865-1010
Environmental Specifications
Enclosure type
NEMA Type 1 – Indoor (sensitive electronic components sealed inside enclosure)
Operational temperature range
-13 to 158 °F (-25 to 70 °C)
Accessories
Remote display
Optional XW System Control Panel monitors and configures all devices connected to Xanbus™ Network
Generator support
Optional XW Automatic Generator Start module connects to Xanbus™
Network. Automatically activates generator to recharge depleted battery
bank or assist inverter with heavy loads
Power distribution & panel conduit boxes
Optional balance-of-systems components for NEC compliant installations, includes pre-wired AC and DC circuit breakers, bus bars
and multiple knockouts for conduit and additional breakers
Regulatory Approvals
UL 1741 1st Edition: 2005 Version CSA 107.1-01
S |